BLDXJ - INDUSTRIAL ENAMEL, 7290

  • MSDS: BLDXJ
  • Manufacturer: RUST OLEUM CORP
  • Product Name: INDUSTRIAL ENAMEL, 7290
  • National Stock Number: 8010-00N019457
Product Identification

Product ID:INDUSTRIAL ENAMEL, 7290
MSDS Date:01/03/1991
FSC:8010
NIIN:00N019457
MSDS Number: BLDXJ

Responsible Party
RUST-OLEUM CORPORATION
11 HAWTHORN PARKWAY
VERNON HILLS, IL 60061
US

Emergency Phone: 708-367-7700

Info Phone: 708-367-7700

Cage: DO883

Contractor
RUST-OLEUM CORPORATION
VERNON HILLS, IL 60061-1583 US

Telephone: 847-367-7700

Cage: DO883

Ingredients

STODDARD SOLVENT

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: 30-55%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM; 9293

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:HARMFUL IF INHALED. MAY
AFFECT THE BRAIN & NERV SYS CAUSING DIZZ, HDCH & NAUS. RPTD
OVEREXPOS MAY LEAD PROGRESSIVELY TO STAG GAIT, CONFUSION, UNCON OR
COMA. CAUSES NOSE & THROAT IRRIT. SKI N/EYE:CAUSES IRRIT WHICH CAN
LEAD TO DERM W/RPTD OVEREXPOS. INGEST:GI IRRIT, NAUS, VOM & DIARR.
(SEE EFTS OF OVEREXP).
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:CHRONIC:REPORTS HAVE SHOWN REPEATED &
PROLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS W/PERMANENT BRAIN &
NERVOUS SYSTEM DAMAGE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE FROM EXPOSURE, RESTORE BREATHING & NOTIFY MD.
EYE:FLUSH IMMEDIATELY W/LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINS. NOTIFY MD. SKIN:WASH AFFECTED AREA W/SOAP & WATER. REMOVE
CONTAMINATED C LOTHING & WASH BEFORE REUSE. INGEST:DO NOT INDUCE
VOMITING. KEEP PERSON WARM, QUIET & GET MD. ASPIRATION OF THIS
MATERIAL INTO THE LUNGS CAN CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE
FATAL.

Fire Fighting

Flash Point:104F,40C
Lower Limits:SEE ING 1
Extinguishing Media:NFPA CLASS B EXTINGUISHERS (CARBON DIOXIDE, DRY
CHEMICAL OR FOAM).
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFT. WATER MAY BE USED TO COOL CLSD CONTRS
TO PVNT PRESS BUILD-UP & (SEE SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS & OPEN FLAME. CLSD CONTRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. DO NOT APPLY TO HOT SURF.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENTILATE AREA
& REMOVE W/INERT ABSORBENT & NONSPARKING TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE LGE
QTYS IN BLDGS DESIGNED & PROTECTED FOR STOR OF NFPA CLASS II
COMBUST LIQS. CONTRS SHOULD BE GROUNDED WHEN POURING.
Other Precautions:EMPTY CONTAINERS MAY BE HAZARDOUS.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED CHEMICAL CARTRIDGE
RESPIRATOR (TC23C) TO REMOVE SOLID AIRBORNE PARTICLES OF OVERSPRAY
& ORGANIC VAPORS DURING SPRAY APPLICATION. IN CONFINED AREAS, USE
NIOSH/MSHA APPROVED SUPP LIED-AIR RESPIRATORS OR HOODS (TC19C)
Ventilation:PROVIDE GENERAL DILUTION OR LOCAL EXHST VENT IN VOLUME &
PATTERN TO KEEP TLV OF HAZ INGREDS BELOW ACCEPTABLE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:IMPERVIOUS CLOTHING TO PREVENT PROLONGED
SKIN CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:POSSIBLE AUTOIGNITION OR EXPLOSION. IF WATER IS USED,
FOG NOZZLES ARE PREFERRED.

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:307F,153C
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER (ETHER=1)
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:51-66

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY OPEN FLAME: CARBON MONOXIDE &
CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF ACCORDING TO LOCAL, STATE & FEDERAL
REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.